Self-Sensing of Bending Strain and Damage in 3-D Braided Composites by Electrical Resistance Measurement
Electrical resistance monitoring of damage has become one of methods of health monitoring.We found that the re-sistance when no damage has occurred is reversible and the resistance is negatively correlated with the deflection.An increase in resistance due to crack generation can be monitored at 70%stress level and a linear increase in resistance due to crack ex-tension at the onset of failure is observed at 90%stress level.In addition to this,the direction of cracking in bending fatigue is propagated from one side to the other.
Fatigue Electrical resistance Failure
HUANG Wei XUE Lingming SUN Baozhong
College of Textiles,Donghua University,Shanghai 201620,China
国际会议
2021 Sino-Africa International Symposium on Textiles and Apparel (SAISTA2021)(2021中非纺织服装国际论坛)
线上
英文
218-221
2021-11-05(万方平台首次上网日期,不代表论文的发表时间)