会议专题

Detection of Inter-turn Short-circuit Faults in PMSMsBased on Instantaneous Reactive Power

  Reliable stator faults diagnosis is important for machine drives.This work presents an inter-turn short-circuit faults detection and faulty phase location method for PMSMs with neutral conductor, based on the percentage of the second harmonics in the three phase instantaneous reactive powers, defined in the abc frame of reference.A faulty PMSM model which is widely used for the detection of inter-turn short-circuits is used to build a simulation setup in MATLAB/Simulink.From the theoretical analysis and the simulations, the second harmonics in instantaneous reactive powers are proven to be the characteristic feature for fault detection.Simulations at different operating conditions show that the percentages of the second harmonics to their dc components in phase instantaneous reactive powers are more reliable than the second harmonic amplitudes themselves for the inter-turn short-circuits detection and location.

faults detection faults location inter-turn short-circuit faults the second harmonic reactive powers

Shaopo Huang Elias G.Strangas Kui Li Feng Niu

State Key Laboratory of EERI, Hebei University of Technology, Tianjin, 300130, China Electrical and Computer Engineering, Michigan State University, East Lansing, MI, 48824, USA

国际会议

The 7th Intrenational Conference on Reliability of Electrical Products and Electrical Contacts(第七届电工产品可靠性与电接触国际会议)

江苏苏州

英文

86-91