会议专题

A Study of Passive Intermodulation in Degraded Coaxial Connectors

  Coaxial connectors generally have slight nonlinear characteristics.The nonlinearity of connectors can cause passive intermodulation (PIM) interference.The connectors will degrade continuously during use,which will aggravate the PIM interference and affect the transmission quality of communication systems.In this paper, a nonlinear behavior model and a prediction model of third-order intermodulation product power of pristine connectors are obtained first.The contact resistance is selected as the index to quantify the degradation degree of the connectors, then the prediction model of third-order intermodulation product power for connectors with various degrees of degradation is developed for the first time.A series of PIM tests are conducted to verify the correctness of the model.This paper provides a theoretical basis for predicting the PIM of degraded coaxial connectors.

Coaxial connector degradation nonlinear characteristics passive intermodulation

Lingyu Bi Jinchun Gao Qiuyan Jin Gang Xie Xiaoming Li

Beijing University of Posts and Telecommunications, Beijing 100876, China The 54th Research Institute of CETC, Shijiazhuang, Hebei 050081, China

国际会议

The 7th Intrenational Conference on Reliability of Electrical Products and Electrical Contacts(第七届电工产品可靠性与电接触国际会议)

江苏苏州

英文

155-159

2019-11-04(万方平台首次上网日期,不代表论文的发表时间)