会议专题

Electrical Life Prediction Method of AC Contactor Based on Fuzzy Neural Network

  The paper studies the electrical life test device with residual electrical life prediction function,which can predict the residual electrical life of AC contactor online.Firstly, the life cycle database of AC contactor under AC4 condition is established.The audio frequency of AC contactor is collected, the spectrum characteristic data is analyzed, the arc energy is collected and calculated when the contactor is broken,and the quality loss data of each contactor is measured.Secondly, the residual electrical life prediction model of AC contactor is established by using the method of fuzzy neural network.After initialization of input data and training of neural network, the residual electrical life of this type of AC contactor can be predicted online.The method can improve the efficiency of electrical life test of AC contactor, reliability and safety of AC contactor,and it has important practical significance for shortening product design cycle.

AC contactor Audio Fuzzy neural network Electrical life Prediction

Yingmin You JinQin Wang Guichu Wu Liang Shu Ziran Wu

State Key Laboratory for Reliability and Intelligence of Electrical Equipment, Hebei University of T State Key Laboratory for Reliability and Intelligence of Electrical Equipment, Hebei University of T The Engineering Technology Research Center of Low-voltage Apparatus of Zhejiang province, Wenzhou Un

国际会议

The 7th Intrenational Conference on Reliability of Electrical Products and Electrical Contacts(第七届电工产品可靠性与电接触国际会议)

江苏苏州

英文

265-269

2019-11-04(万方平台首次上网日期,不代表论文的发表时间)