Correlation between Load Current Mode and Electrical Contact Resistance of a Closed Pair of Contacts

  The electrical contact resistance of closed contact pair is dependent on contact material physical characteristics, contact type (sphere-flat or flat-flat),contact surface status (clean or contaminated), but also contact current and mechanical load during measuring.The relationships between contact resistance and load current and load force with the use of DC mode and non-constant current mode measurement method are compared in this paper.The variations in thermoelectric voltage of contact pairs as a function of time with constant force load are presented.

Contact resistance Measurement Load current Delta mode Thermoelectric voltage

Chuwan Xiao Teng Wang Dazhao Yu Ming Li Sihuan Wang Wanbin Ren

Naval Aviation University Yantai 264001 China AVIC China Aero-poly Technology Establishment Beijing 100000 China Harbin Institute of Technology Harbin 150001 China