会议专题

Study on Lifetime of Electromagnetic Relay between Resistive Load and Inductive Load

  Based on theory analysis, it is generally believed that the lifetime of electromagnetic relays under resistive load are better than that under same level current inductive load, but we found that the lifetime of some relay products the results were inverse.In this paper, the relays with different current level were selected as the study object.Through analyzed the temperature rise, morphology of the contact (after lifetime) and the product structure, it was found that the product structure greatly determines the difference of lifetime between resistive load and inductive load.And verified that by reducing the load current or adjusting the relay overtravel could reduce or even reverse the difference of lifetime between the resistive load and the inductive load.The whole study is helpful for product design, product performance evaluation and customer applications.

Relay Electrical lifetime Resistive load Inductive load Temperature rise Arc energy Contact morphology

Vincent Fang Wei Gao

Industrial Technology Lab, Tyco Electronics (Shenzhen) Co., Ltd., China

国际会议

The 7th Intrenational Conference on Reliability of Electrical Products and Electrical Contacts(第七届电工产品可靠性与电接触国际会议)

江苏苏州

英文

388-391

2019-11-04(万方平台首次上网日期,不代表论文的发表时间)