Fault Tolerant Control for Five-Phase Synchronous Reluctance Motor by Third Harmonic Current Injection
Recently,most fault tolerant controls have been applied in permanent magnet synchronous motors(PMSM)and permanent magnet assisted synchronous reluctance motors(PMa-SynRM),however,previous fault tolerant controls are hard to apply into synchronous reluctance motor(SynRM).This is because that torque ripple under these fault tolerant controls is unacceptable.Hence,this paper presents a new fault tolerant control for a five-phase SynRM to reduce torque ripple under single phase fault.Process of calculating third harmonic current is the critical point of this proposed method,which is obtained by neglecting changes of inductance because of small magnitude of third harmonic current.The further Finite Element Analysis(FEA)and experimental results validate the availability of proposed method.
Synchronous reluctance motor Fault tolerant control Harmonic injection
Guohai Liu Jiajun Ni Qian Chen
School of Electrical and Information Engineering,Jiangsu University,Zhenjiang,China
国际会议
江苏镇江
英文
529-536
2019-09-20(万方平台首次上网日期,不代表论文的发表时间)