Finite Element Simulation of the Shear Effect of Ultrasonic on Heat Exchanger Descaling
The shear effect on the interface of metal plate and its attached scale is an important mechanism of ultrasonic descaling,which is caused by the different propagation speed of ultrasonic wave in two different mediums.The propagating of ultrasonic wave on the shell is simulated based on the ANSYS/LS-DYNA explicit dynamic analysis.The distribution of shear stress in different paths under ultrasonic vibration is obtained through the finite element analysis and it reveals the main descaling mechanism of shear effect.The simulation result is helpful and enlightening to the reasonable design and the application of the ultrasonic scaling technology on heat exchanger.
Shaolv Lu Zhihua Wang Hehui Wang
School of Mechanical and Power Engineering,East China University of Science and Technology,Shanghai,China
国际会议
上海
英文
1-5
2017-12-28(万方平台首次上网日期,不代表论文的发表时间)