会议专题

DESIGN AND ANALYSIS OF A NOVEL MEMS PIEZOELECTRIC ACCELEROMETER FOR VECTOR HYDROPHONE

  A novel ZnO film accelerometer based composite beam with double U grooves was proposed for MEMS vector hydrophone to increase the sensitivity.The sensitivity analysis and structure optimization were carried out by finite element method (FEM).The optimized thickness of ZnO film is around 67% of the thickness of silicon layer.The length of the U groove has little effect on the average stress of ZnO film, while the width of U groove has obvious effect on the average stress.The average stress in ZnO film of the new structure is 1.5 times of that with regular piezoelectric composite cantilever structure, and three times output voltage can be further obtained by the electrode series connection.Based on the above-mentioned factors, the sensitivity of accelerometer with double U grooves is 4.5 times of that with regular cantilever, and the acoustic sensitivity of the vector hydrophone can be increased by 13dB.

MEMS Piezoelectric vector hydrophone U grooves FEM

Dong-ning LI Qing-qing FAN Jun-hong LI Wei REN

State Key Laboratory of Acoustics, Chinese Academy of Sciences, Beijing 100190, China;University of State Key Laboratory of Acoustics, Chinese Academy of Sciences, Beijing 100190, China

国际会议

The 2019 Symposium on Piezoelectricity,Acoustic Waves and Device Applications(2019(第13届)全国压电和声波理论及器件技术研讨会)

哈尔滨

英文

235-240

2019-01-11(万方平台首次上网日期,不代表论文的发表时间)