Characteristics of Slurry Infiltrated Fiber Reinforced Cementitious Composite with varying Fire-resistant Fibers under High Temperature Exposure
Due to the development of construction technology, social structures are becoming larger and the functions of structures are becoming diverse and complex.However, unexpected accidents such as terrorism, collision, explosion and fire events have been increasing.A high performance fiber reinforced cementitious composite such as SIFRCC (Slurry infiltrated Fiber Reinforced Cementitious Composite) can be used for both fire and explosion resistant structures.This study analyzed the characteristics of SIFRCC under a static loading condition.The material variables included fire-resistant fiber contents and exposure temperatures.
Seulgi Kim Haekook Jung Seungwon Kim Yongjae Kim Cheolwoo Park
Department of Civil Engineering, Kangwon National University, Samcheok, KOREA, REPUBLIC OF
国际会议
福州
英文
329-333
2018-11-04(万方平台首次上网日期,不代表论文的发表时间)