MODELLING OF CONCRETE-FILLED FRP TUBES CONSIDERING NONLINEAR BIAXIAL TUBE BEHAVIOR

  Concrete-filled fiber-reinforced polymer(FRP)tubes(CFFTs)are an attractive form of hybrid members.The FRP tube in CFFTs is typically manufactured by filament-winding,with the fibers suitably oriented for the desired mechanical properties.Such members have many advantages over traditional columns.including their excellent corrosion resistance and ductility.As a result.a significant number of experimental/theoretical studies have been conducted on the behavior of CFFTs under axial compression.In the existing theoretical work on concrete-filled FRP tubes under axial compression.the FRP tube has commonly been assumed to have linear-elastic behavior.and has often been taken to be under a uniaxial stress state(i.e.,hoop tension),especially when the fibers are oriented close to the hoop direction.However.in reality,FRP tubes in CFFTs are subjected to a state of biaxial stresses and may exhibit significantly nonlinear behavior.This paper presents an improved model for the axial compressive behavior of CFFTs with the nonlinear behavior of the FRP tube under biaxial stresses(hoop tension in combination with axial compression)duly accounted for.Comparison between the proposed model and test results indicates that the proposed model leads to much more accurate predictions than when the biaxial nonlinearity of the FRP tube is ignored for certain cases although the improvement in accuracy is much smaller for other cases.

Filament-wound FRP tube Biaxial stress state Nonlinear analysis Confinement Concrete

P.Xie G.Lin J.G.Teng T.Yu

Department of Civil and Environmental Engineering,The Hong Kong Polytechnic University,Hong Kong,Chi School of Civil,Mining and Environmental Engineering,University of Wollongong,Australia

国际会议

the Sixth Asia-Pacific Conference on FRP in Structures (APFIS2017)(第六届亚太纤维增强复合材料结构工程国际会议暨第十届全国建设工程FRP应用学术交流会)

新加坡

英文

1-7

2017-07-19(万方平台首次上网日期,不代表论文的发表时间)