Data Mining on Numeric Error in Computerized Physician Order Entry System Prescriptions

This study revealed the numeric error patterns related to dosage when doctors prescribed in computerized physician order entry system.Error categories showed that the ‘6’,‘7’,and ‘9’ key produced a higher incidence of errors in Numpad typing,while the ‘2’,‘3’,and ‘0’ key produced a higher incidence of errors in main keyboard digit line typing.Errors categorized as omission and substitution were higher in prevalence than transposition and intrusion.
Medical order entry systems Medication errors Numeric
Wu Xue Wu Changxu
Peking University,School of Nursing,Beijing,China Department of Industrial and Systems Engineering,State University of New York(SUNY)-Buffalo,NY,USA
国际会议
第十六届世界医药健康信息学大会((MEDINFO2017)、第二届世界医药健康信息学华语论坛(WCHIS 2017)、第15届全国医药信息学大会(CMIA 2017)
苏州
英文
1386-1386
2017-08-21(万方平台首次上网日期,不代表论文的发表时间)