Research on the Exoskeleton Robot Foot Pressure Detection System based on Curve Fitting

  Wearable exoskeleton foot pressure detection system has great significance for human motion information detection and gait recognition.In this paper,the use of resistive pressure sensor to make up for the existing lower extremity exoskeleton pressure sensor input and output non-linear error,which cant accurately detect the lack of plantar pressure changes,through the theoretical calculation to determine the feasibility of curve fitting method,Introduced foot pressure detection system design.The results show that the method of collecting the sample data is obvious,the curve fitting system is linear and the reliability is high,which is suitable for the plantar pressure detection system.

Exoskeleton Plantar pressure Curve fitting Pressure sensor

Chen Fei Dezhang Xu Zhihong Wang Buyun Wang

AHPU Institute of Technology Robotic Industry Wuhu,Anhui Province,China AHPU Institute of Technology Robotic Industry Wuhu,Anhui Province,China;School of Mechanical and Aut