Cause analysis of exciter cover connecting bolt fracture happening in nuclear power plants
In view of the failure accidence of Exciter cover connecting bolt fracture happening in Nuclear Power Plants,the failure of bolt was analyzed in terms of the metallurgical and fractogragh by means of optical microscopy,scanning electron microscopy and hardness test.The present investigation indicated that the fracture mechanism was fatigue caused by exciter cover vibration generated in the process of running.
bolt fracture vibration fatigue
Bingkun Shan Yan Li Long Miao
Liaoning Hongyanhe Nuclear Power co.,LTD;No.127,Nanshan Road,Zhongshan District,Dalian Suzhou Nuclear Power Research Institute;No.1788,Xihuan Road,Gusu District,Suzhou
国际会议
沈阳
英文
89-96