Cause analysis of exciter cover connecting bolt fracture happening in nuclear power plants

  In view of the failure accidence of Exciter cover connecting bolt fracture happening in Nuclear Power Plants,the failure of bolt was analyzed in terms of the metallurgical and fractogragh by means of optical microscopy,scanning electron microscopy and hardness test.The present investigation indicated that the fracture mechanism was fatigue caused by exciter cover vibration generated in the process of running.

bolt fracture vibration fatigue

Bingkun Shan Yan Li Long Miao

Liaoning Hongyanhe Nuclear Power co.,LTD;No.127,Nanshan Road,Zhongshan District,Dalian Suzhou Nuclear Power Research Institute;No.1788,Xihuan Road,Gusu District,Suzhou

国际会议

5th International Symposium on Materials and Reliability in Nuclear Power Plants & Symposium on Water Chemistry and Corrosion in Nuclear Power Plants in Asia-2017 & 3rd Asian Forum on Material Aging Issues in Nuclear System(2017第五届核电厂材料与安全可靠性国际研讨会 )

沈阳

英文

89-96