Preliminary research on the influence of deposited corrosion products on cladding corrosion performance
Corrosion products in primary coolant circuit deposited on fuel rod cladding surface can cause cladding corrosion anomaly.Considerable deposited corrosion products on cladding will increase local cladding temperature and speed up corrosion rate which have destructive effect on cladding corrosion performance.In order to evaluate the influence of crud layer(formed by deposited corrosion products)on cladding performance,this paper focuses on the research of crud deposition mechanism and corrosion product deposition modeling.Some investigations on the relationship between crud thickness and crud deposition conditions have been made to evaluate cladding corrosion performance.The results indicate that the maximum core crud thickness will not exceed 50μm during target cycle,and could ensure the cladding integrality.
Crud Deposition mechanism Deposition models Cladding performance
Jie Wang Xiaoyan Wei Shao fang Lin Changzheng Li Yongjun Deng
China Nuclear Power Research Institute.Nuclear Fuel R&D Center,Chengdu,Sichuan,China
国际会议
沈阳
英文
275-283
2017-09-26(万方平台首次上网日期,不代表论文的发表时间)