Research on the De-icing Efficiency of Electrothermal Fan for the Post Insulator
The de-icing method of hot blast has anadvantage that it can be used while the electric equipment is running,butit needs further study for engineering application.In this paper,a series of tests were conducted to study the de-icingprocess ofhot blast.During the tests,wehave recorded the time ofcompletelyde-icingfor each one insulator and analyzed the de-icingefficiency of the electrothermal fanwhen its in the condition of glaze icing.Through the de-icingeffect test and calculating the de-icing effi-ciency of electrothermal fan under the different icing thickness(10mm,20mm,30mm respectively)on three kinds of post insula-tor,we found that the average de-icingefficiency of the electro-thermal fanused in this test is about 6.5%,and there is no obvious relationship between de-icingefficiency and thetype of insulator or icing thickness.The relevant conclusions obtained in this paper can provide some references for practical application.
De-icing Efficiency Post Insulator Electrothermal Fan
ZHAO Yulai HU Jianlin XU Ke
State Key Laboratory of Power Transmission Equipments & System Security and New Technology,College of Electrical Engineering,Chongqing University,Chongqing 400030,China
国际会议
重庆
英文
1-6
2017-09-25(万方平台首次上网日期,不代表论文的发表时间)