Reason Analysis and Precautionary Measures of Abnormal Power Factor
Aiming to decrease power loss,it is common to install reactive compensation devices to improve power factor and decrease the loss.As a result of that reactive compensation devices will work in overcompensation state(which means the energy meter works in IV quadrant),problems like increasing wire loss and decreasing voltage may do harm to the safety and stable operation of electrical devices.This thesis combined cases of exceptionally low power factor caused by over compensation,and did analysis on its harm and countermeasure in detail,so that the objection of loss decrease and energy saving would be reached and social economic benefit would be increased.
over compensation power factor operation mode countermeasure
Chang Shiliang Zhang Jiaming He Bei
Electric Power Research Institute State Grid Chongqing Electric Power CO.Yubei District,Chongqing 401123,China
国际会议
重庆
英文
1952-1955
2017-03-25(万方平台首次上网日期,不代表论文的发表时间)