SIMULATED BALLAST WATER TREATMENT BY ELECTROLYSIS PROCESS
This work investigates the use of electrolysis for ballast water treatment.The total residual oxidant(TRO)generation and microalgae inactivation were examined,and the effects of hydraulic residence time(HRT),current density,and water salinity were evaluated.Results show that TRO could be generated by seawater electrolysis,and the produced TRO concentration was positively correct with HRT,current density,and water salinity.The increase in water salinity decreased energy consumption,while the effects of HRT and current density on energy efficiency were complex.The persistence of TRO resulted in algae inactivation in the effluent.Considering efficiency and cost,electrolysis technology has advantages in ballast water treatment.
Ballast water electrolysis . total residual oxidant algae inactivation
Donghai Wu Guanghua Lu Ran Zhang Zhou Chao Xinghou Shen Wei Wang
Key Laboratory of Integrated Regulation and Resource Development on Shallow Lakes of Ministry of Edu State Key Laboratory of Urban Water Resource and Environment,Harbin Institute of Technology,P.O. Box Henan Province Hydrology and Water Resources Bureau,Zhengzhou,450004,China
国际会议
2016 International Symposium on Civil and Environmental Engineering(2016年土木与环境工程国际研讨会)
武汉
英文
144-147