会议专题

SENSITIVITY CHARACTERISTICS OF 1-3 PIEZOELECTRIC COMPOSITE HYDROPHONES OVER A WIDE FREQUENCY RANGE

  The conventional hydrostatic model based on static analysis is frequency-independent and inadequate to fully evaluate the present hydrophones full range of receiving sensitivity.To expand the operating limits of the hydrostatic model, a dynamic fluid-structure interaction model for analyzing the sensitivity of piezoelectric hydrophones is presented.An analytical solution that governs the receiving sensitivity of the piezoelectric hydrophones over a wide frequency range, in both the non-resonance frequency and the resonance frequency regions, is derived.The theoretical result shows that the derived receiving sensitivity agrees well with the hydrostatic model.Additionally, the experimental results verify the theory presented in resonance frequency range.

Piezoelectric hydrophone Receiving sensitivity Dynamic model

De-ping ZENG Hua WANG Ying-qi SUN Xue-mei GAO Zeng-tao YANG

State Key Laboratory of Ultrasound Engineering in Medicine Co-founded by Chongqing and the Ministry of Science and technology, Chongqing Key Laboratory of Biomedical Engineering, College of Biomedical Engineering, Chongqing Medical University, Chongqing Collaborative Innovation Center for Minimally-invasive and Noninvasive Medicine,Chongqing 400016, China

国际会议

The 2017 Symposium on Piezoelectricity,Acoustic Waves and Device Applications(2017全国压电和声波理论及器件技术研讨会)

成都

英文

251-254