Break Arc Characteristics of AgSnO2 Contact Pairs at Contact Opening Speeds up to 200mm/s in DC Load Conditions Under External Magnetic Field Application

  Break operations of AgSnO2 contact pairs were conducted in a DC inductive circuit (L=5.7mH) at 14V-11A and in a DC resistive circuit at 14V-13A under different contact opening speeds up to 200 mm/s and with/without external magnetic field application in uncontrolled laboratory atmosphere, and break arc voltage waveforms were observed.After the experiments, averages for total arc durations as well as metallic phase and gaseous phase (when observed) durations were calculated at each condition.The results show that increases in the contact opening speeds lead to reductions in metallic phase durations in almost inverse proportion relationship, while application of external magnetic field causes gaseous phases to become shorter.

Electrical contacts Break arc Magnetic field Contact opening speed Metallic phase Gaseous phase

Makoto Hasegawa Seika Tokumitsu

Department of Opto-Electronic System Engineering Chitose Institute of Science and Technology, Chitose, Hokkaido, 066-8655,Japan

国际会议

The 6th Intrenational Conference on Reliability of Electrical Products and Electrical Contacts(第六届电工产品可靠性与电接触国际会议)

江苏常熟

英文

11-15