会议专题

Analysis on Three-dimensional Transient Temperature Field of Permanent Magnet Based on ANSYS

  Compared with the traditional electromagneti-c contactor, the permanent magnet (PM) contactor has the salient merits include energy saving, and noise free.However the PM is easy to be affected by temperature, which affects the dynamic characteristics of PM contactor.In this paper, based on the finite element simulation software ANSYS, the analysis on three-dimensional transient temperature field of PM actuator is carried on.Firstly, the thermodynamics, heat source and heat dissipation of the PM actuator are studied.Secondly, during the switching-on process, the simulation on three dimensional transient temperature field of PM is carried out based on ANSYS.Finally, the effect of temperature on the dynamic characteristics of PM contactor is explored.The results show that the temperature of PM has a great influence on the dynamic characteristics of PM contactor.The research results have important significance to improve the reliability and performance of the PM contactor.

PM contactor temperature field dynamic characteristic movable core

Changchun Chi Hailiang Ji Hongsong Liu Hengqing Huang

School of electrical engineering Shanghai DianJi University, Shanghai, 201306, China

国际会议

The 6th Intrenational Conference on Reliability of Electrical Products and Electrical Contacts(第六届电工产品可靠性与电接触国际会议)

江苏常熟

英文

121-124

2017-04-18(万方平台首次上网日期,不代表论文的发表时间)