会议专题

A Method Based on 2DOF-IMC to Voltage Low-Frequency Oscillation Suppression in High-Speed Railway Traction Network

  Aiming at the low-frequency oscillation of traction network caused by the high-speed railway electric motor units (EMUs), when transient current control strategy (TCCS) based on traditional PI controller is adopted by the line-side converter (LSC) of the EMUs, by analyzing the PI controller parameter adjustment, it is found that this suppression measure has its limitations. In order to overcome the above problem, this paper brings internal model control (IMC) into the TCCS, and according to the internal model control principle, a two-degree-of-freedom (2DOF) internal model controller is designed to replace the traditional PI controller in the TCCS. Then comparing the performance characteristics of TCCS based on traditional PI controller with TCCS based on 2DOF-IMC. Finally, the EMUs adopting the two control strategies are applied to the time-domain simulation model of the train-grid respectively, it can be found that TCCS based on 2DOF-IMC provides better tracing and load disturbance regulation characteristics, in addition, it is able to suppress the low-frequency oscillation of high-speed railway traction network effectively.

train-grid system low-frequency oscillation electric motor units line-side converter internal model control

Chen Daopin Ou Xiaomei Leng Yue Wang Zhiqi

Foshan Power Supply Bureau,Guangdong Power Grid Co.,Ltd.,Foshan 528000,Guangdong Province,China School of Electrical Engineering and Information,Sichuan University,Chengdu 610065,Sichuan Province,

国际会议

2016中国国际供电会议(CICED2016)

西安

英文

1-5

2016-09-01(万方平台首次上网日期,不代表论文的发表时间)