Harmonic current source based on fractional order FIR repetitive control
Harmonic current sources (HCS) that can provide variable-frequency and amplitude output current are widely used in automatic testing of the electrical equipments. Digital repetitive control (RC) can achieve zero steady-state error tracking of any periodic signal with known integer period , hence, its suitable for harmonic control, but it usually fails to provide precise tracking of variable frequency periodical waveform with fractional time delay. In this paper ,a fraction order delay FIR filter based on Lagrange interpolation is used to approximate the factional delay items in RC. The design criteria is summarized in a simple form, and the stability of Fractional order RC is also analyzed in this paper, experiments is conducted to verify the effectiveness of the proposed FORC strategy.
harmonic current source repetitive control Fraction-order FIR
LEI Wan-jun WANG Hua-jia Jiang Yong-bin CHENG Nie Chen Ming-feng WANG Yue
State Key Laboratory of Electrical Insulation and Power Equipment,Xian Jiaotong University,Xian 71 State Grid Shandong Electric Power Company,Electric and science research Institute,Jinan 250003 Shan
国际会议
西安
英文
1-5
2016-09-01(万方平台首次上网日期,不代表论文的发表时间)