Modification Strain-Based Failure Assessment Diagram for High Strength Pipeline Steel
The strain-based failure assessment diagram (SB-FAD) has been developed to predict failure due to high plastic strains.This paper validates the SB-FAD by finite element results for high strength pipeline steel (X80,X80HD,and X90) with four representative specimens (CT,CCP,DECP,and SCEP) of different crack sizes,respectively.The influence of material properties,geometries and crack sizes on failure assessment curves were compared and analyzed.Meanwhile,the modified Option-1 curve of SB-FAD is given in this paper.The results showed that the modified Option-1 curve of SB-FAD is more accurate when the value of abscissa Dr is small and more conservative when the value of abscissa Dr is large.
strain-based analysis failure assessment diagram pipeline steel fracture defects
Junlin Shi Jianping Zhao Weijie Jiang
School of Mechanical and Power Engineering,Nanjing Tech University,Nanjing,Jiangsu,211816,China
国际会议
2016 International Symposium on Structural Integrity,ISSI—2016(2016国际结构完整性研讨会)
天津
英文
33-40
2016-05-26(万方平台首次上网日期,不代表论文的发表时间)