会议专题

Semi-Open Thermal Protection Scheme of Electronics in Nuclear Rescue Robot

  Thermal management of electronics is quite important for safe operation of nuclear rescue robot.However,the ambient temperature of the nuclear robot in the site of nuclear accident will suffer an alternation between ordinary and elevated temperature.Traditional phase change material (PCM) based closed scheme for thermal protection is not suitable due to the capacity limitation of PCM.Open scheme with forced air cooling or water cooling is not acceptable either,because it cannot operate in high temperature.Therefore,a semi-open thermal control scheme is proposed by using silica aerogel for heat insulation,PCM for heat absorption,and Nickel-titanium alloy spring as temperature switch.An investigation on different ambient temperature,laying angle,melting point of PCM and heat power is conducted.The results showed that,compared with the PCM-based closed scheme,our design can provide 19.23% prolonged safe working hours,which can improve the reliability of electronic devices.

semi-open scheme electronics nuclear rescue robot thermal protection

Ke Sun Yanlong Han Weiling Luan

Key Laboratory of Pressure Systems and Safety,Ministry of Education,East China University of Science and Technology,No. 130 Meilong Road Shanghai,200237,China

国际会议

2016 International Symposium on Structural Integrity,ISSI—2016(2016国际结构完整性研讨会)

天津

英文

405-409

2016-05-26(万方平台首次上网日期,不代表论文的发表时间)