会议专题

Investigation of Low-cycle Fatigue Behavior on Candidate Alloy C263 for A-U.S.C Boiler

  This study firstly got the full range uniaxial constitutive relationship by uniaxial tensile tests, based on FAT (finite element auxiliary test) method, up to failure on candidate alloy C263 for A-U.S.C boiler at room temperature,700℃ and 730℃ , respectively, which can be applied as basic data for large deformation analysis.A series of low cycle fatigue tests under strain controlling on the alloy at three temperatures had been carried out, some key mechanical properties such as Mason-Coffin model for life prediction and cyclic constitutive cures were given.Results of tests showed that tensile properties oftbe alloy at room temperature are better than those at elevated temperatures and there is little difference between 700℃ and 730℃.The alloy behaves obvious cyclic-hardening during low cycle fatigue tests at three temperatures, and fatigue-life is reduced as temperature is increased.

A-U.S.C boiler candidate alloy C263 low cycle fatigue under strain control elevated temperature full range uniaxial constitutive relationship Mason-Coffin model for life prediction

Yang Wen Yang Huachun Bao Chen Cai Lixun Chen Hui Qi Shuang Yao Di

Dongfang Boiler Group Co., Ltd.643001, Zigong, Sichuan, China Mechanics and Engineering Institutes, Southwest Jiaotong University, Chengdu, Sichuan, China

国际会议

The 9th China-Japan Bilateral Symposium on Hiigh Temperature Strength of Materials(第九届中日双边高温材料强度国际学术研讨会)

长沙

英文

83-88

2016-10-16(万方平台首次上网日期,不代表论文的发表时间)