会议专题

Study of High Precision Measurement System in Pulsed Laser Ranging

  To improve the accuracy of time interval measurement in pulsed laser ranging system,a method which combines clock counting and differential delay line based on Field Programmable Gate Array (FPGA) is used in time interval measurement.FPGA sets up two delay lines in its internal,one of them consists of several buffers; another consists of several D flip-flops.The time delay between them serves as the smallest unit of time interval measurement,which is the step length of measuring time interval within half a clock cycle.Compared with clock counting method,this method put time interval measurement accuracy up to ten times.The experiment results show that time interval of system measurement reach at ±300 ps,and 3 cm measuring distance precision is achieved,which means that the method can satisfy the requirements of high precision ranging.

time interval measurement FPGA differential delay line distance measurement precision

Zhang Yanmei Qiao Tong Qian Ruihai Wang Yue

Beijing Institute of Technology, Haidian District, Beijing, 100081 China China North Industries Corp, Xicheng District, Beijing, 100053 China

国际会议

2016 2nd International Conference on Mechanical, Electronic and Information Technology Engineering(2016机械、电子和信息技术国际会议)

重庆

英文

5-9

2016-03-21(万方平台首次上网日期,不代表论文的发表时间)