Numerical Evaluation of the Effectiveness of the Air Chamber of Shoes Pad for Diabetes with FE-SPH Method
The object of this study is to utilize FE-SPH method to simulate the dynamic behavior of the air chamber of shoes pad for diabetes during footing process.The shoes pad numerical models are discrete as FE mesh,and the air inside is modeled as SPH particles.The fluid structure interaction analysis between air and the shoes pad is carried out with contact algorithms.This explicit dynamic analysis is run on ANSYS software.Results show that: when the shoes pad is loaded,the velocity field concentrated on the central region of air chamber,and the particles in the fringe maintain a zero speed,which means the air flow out in the central region instead of the fringe.Thus,the shoes pad is effective in supplying air for the foot of diabetes.
Shoes pad for diabetes Fluid structure interaction (FSI) analysis Finite element (FE) analysis Smoothed particle hydrodynamics (SPH).
Xin Ye Linan Zhang Zaobing Xu Zengtao Hou Xueling Bai Peng Shang
Centre for Translational Medicine Research and Development,Shenzhen Institutes of Advanced Technology Chinese Academy of Sciences,Shenzhen 518055, China
国际会议
The Third International Coference on Health Information Science(HIS2014)2014年第三届健康信息学国际学术会议
深圳
英文
20-28
2014-04-22(万方平台首次上网日期,不代表论文的发表时间)