Influence research of fabrication errors on modal amplitude in a dual-mass silicon micro-gyroscope
Influence of fabrication errors on modal amplitude in a dual-mass silicon micro-gyroscope is present in this paper. Firstly, the structure and operation principle a dual-mass silicon micro-gyroscope is introduced. Then the equation of amplitude ratio between left and right proof mass is deduced. Finally, the simulation analysis of fabrication errors on modal amplitude is implemented. The simulation results show the amplitude ratio is decreased to -1.2741 when the left proof mass error is 5% in anti-phase driving mode. The amplitude ratio is increased to -0.800 when the left stiffness error is 5% in anti-phase sensing mode.
silicon micro-gyroscope fabrication error amplitude ratio
Hu Di Yang Bo Dai Bo
School of Instrument Science & Engineering, Southeast University, Nanjing 210096, China;Key Laboratory of Micro-Inertial Instrument and Advanced Navigation Technology, Ministry of Education, Nanjing 210096, China
国际会议
重庆
英文
1199-1203
2015-12-18(万方平台首次上网日期,不代表论文的发表时间)