Study on Reliability of Magnetic Slot Wedge Operation in Large Wind-Power Generator

  The use of magnetic slot wedge in electric machines often goes wrong.Its easy to fall off and crush because of the force.This has serious impact on the reliability of the electric machines running.Aiming at various faults in the electric machine running conditions, with a 2.5 MW squirrel-cage asynchronous wind-power generator as an example, using ANSOFT electromagnetic field simulation software, starting from its failure mechanism, the radial and tangential electromagnetic force of magnetic slot wedge in the complex air-gap magnetic field was analyzed.The reliability of magnetic slot wedge in the electric machine running process was illustrated by comparing the analysis result of the same phase and different phase slot wedges working status in the short-circuit fault conditions with the capacity of magnetic slot wedge to bear the force.Thus the failure of electric machine operation is reduced, the lifetime is improved and the reliability of electric machine operation is enhanced.The study has high engineering use value and theoretical significance.

magnetic slot wedge fault condition electromagnetic force reliability

Changchun Chi Zhenhai Zhang Zhengbing Lian Shiliang Shao Jiaojiao Liu

Shanghai Dianji University, Shanghai, 200240

国际会议

The 5nd Intrenational Conference on Reliability of Electrical Products and Electrical Contacts(第五届电工产品可靠性与电接触国际会议)

温州

英文

145-150

2014-11-16(万方平台首次上网日期,不代表论文的发表时间)