Research on Contacts Contact Pressure Sensor Calibration Techniques Based on Pendulum-Typed Metal Ball Impact Method

  The PVDF piezoelectric film is used to be a contact pressure sensor, it is very difficult to carry on the static calibration.In order to find the relationship between the output voltage of a contact pressure sensor and the actual contact pressure on the contact, this paper introduces a quasi static calibration technique based on pendulum-typed metal ball impact method.This method is simple, reliable, easy to operate, and the least square method are used to fit the data.A calibration bench was designed and a contact pressure sensor dynamic calibration system was set up.The calibration was completed in the laboratory, and the calibration curve of the output voltage of a contact pressure sensor and the actual contact pressure on the contact was obtained, and the conclusion is that the relation of the two is linear.The conclusion provides a valuable reference for further research on the relationship between instant contact pressure, the contact resistance, vibration and other parameters.

contact pressure PVDF piezoelectric film static calibration calibration curve

Junfeng Li Shaojie Guo Tong Chen Chunqian Zhang Xiuping Su

Province-Ministry Joint Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability Province-Ministry Joint Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability

国际会议

The 5nd Intrenational Conference on Reliability of Electrical Products and Electrical Contacts(第五届电工产品可靠性与电接触国际会议)

温州

英文

341-344

2014-11-16(万方平台首次上网日期,不代表论文的发表时间)