Failure Analysis and Redesign on Jacketed Aggregated Kettle of Propylene
Jacketed aggregated kettle is the key equipment of polypropylene reaction setting.The main failure of the equipment is cracks and leakage in the kettle wall near the lower thermometer pipe branch, which is a widespread phenomenon in this refinery.The failure pattern is low cycle fatigue cracking which results from cycle vibration and high stress concentration.Incorrect design of the jacket structure which resulted in edge stress is responsible for the low cycle fatigue.An improved measurement which is available and simple was introduced.
Aggregated kettle of propylene Low cycle fatigue Failure
Jingqiang Yang Kaishu Guan
School of Mechanical Engineering,East China University of Science and Technology,Shanghai 200237,China
国际会议
2014 International Symposium on Structural Integrity,ISSI2014(2014国际结构完整性学术会议)
兰州
英文
199-206
2014-08-20(万方平台首次上网日期,不代表论文的发表时间)