会议专题

Efficient Method for Field Coupling to Nonuniform Transmission Line Using Cascaded SPICE Model

  This paper presents a method of equivalent cascaded SPICE model for external field coupling with nonuniform transmission line.Two nonuniform transmission lines excited by an external EMP with different incidences have been studied to validate its accuracy and efficiency.The results show that the induced voltages obtained by the proposed method agree well with those via the software CST even when the segment number is up to three and the proposed method has higher efficiency.Due to the application of SPICE model and directly computation in the time domain,this method allows for the analysis of nonuniform transmission line terminated with nonlinear loads and integrated circuits.

Haiyan Xie Jianguo Wang Yong Li Hongfu Xia Chun Xuan

Northwest Institute of Nuclear Technology,P.O.Box 69-12,Xian,Shaanxi 710024,China Northwest Institute of Nuclear Technology,P.O.Box 69-1,Xian,Shaanxi 710024,China

国际会议

Progress in Electromagnetics Research Symposium 2014(2014年电磁学研究新进展学术研讨会)

广州

英文

2622-2627

2014-08-01(万方平台首次上网日期,不代表论文的发表时间)