Honeycomb Ventilation Grill Shielding Effectiveness Measuring Methodology
In the article assessment methodology of shielding effectiveness of ventilation panels of small overall dimensions made in the form of honeycomb with the use of the computer simulation method has been presented.Methodology and description of simulation environment for measuring shielding effectiveness of ventilation panels by the method of computer simulation have been shown.Final effect of simulation software operation is characteristics of shielding effectiveness of a tested ventilation panel in the frequency function.In order to conduct validation of simulation software values of shielding effectiveness for a selected ventilation panel obtained by the computer simulation method have been compared with results obtained due to tests in real laboratory conditions.
Leszek Nowosielski Cezary Piotrowski
Faculty of Electronics,Military University of Technology Gen.S.Kaliskiego 2 str.,Warsaw 00-908,Poland
国际会议
Progress in Electromagnetics Research Symposium 2014(2014年电磁学研究新进展学术研讨会)
广州
英文
2692-2698
2014-08-01(万方平台首次上网日期,不代表论文的发表时间)