会议专题

Interface modification of Kevlar fiber/epoxy resin by cryogenic treatment

  In this study, Kevlar fiber compared with Kevlar fiber/epoxy micro-composite were selected to undertake interface modification through two different methods known as the temperature program controlled method (TPCM) and quenching method (QM).The interracial shear strength (IFSS) of the modified Kevlar with epoxy resin was characterized by means of the micro-bond test and the result showed an increase of 12.7% (TPCM) and 5.5% (QM) respectively.The surface morphology of the cryo-treated and untreated fibers was observed by atomic force microscope (AFM).It showed obvious improvement of surface roughness after cryogenic treatment which in agreement with the result of IFSS.However, the IFSS values of micro-composites significantly increased by 35.2% (TPCM) and 19.9% (QM) showing great potency of cryogenic treatment on interface modification of Kevlar fiber and epoxy resin system.

Cryogenic treatment Kevlar fiber IFSS AFM

Yinnan Zhang Qiaole Hu Zimeng Zhang Yun Zuo Fujun Xu

College of Textiles, Donghua University, Shanghai 201620, China College of Textiles, Donghua University, Shanghai 201620, China;Shanghai Key Laboratory of Advanced

国际会议

2014 Annual Shanghai Graduate Student Academic Innovation Forum of Fashion and Textile,The 8th International Innovation Forum of Textile & Clothing(2014上海纺织服装创意创新研究生学术论坛暨第八届纺织服装创新国际论坛)

上海

英文

100-102

2014-07-11(万方平台首次上网日期,不代表论文的发表时间)