会议专题

MODELING OF FOULING IN CFB BOILERS

  This paper describes FoulEst-in-house model that estimates fouling rate in convective back-pass of CFB boilers.FoulEst model incorporates in-house experience on fouling from several commercial CFB boilers firing coal, biomass, peat and waste as well as from contemporary literature.From those, this paper focuses on two CFB boilers co-firing agricultural residues with coal or wood, respectively.In particular, the paper discusses the model capabilities to predict the fly ash generation, deposit composition, and fouling rate for these two cases.Furthermore, the paper shows experimental validation results produced in well controlled laboratory conditions of a deposit simulator test rig.

Vesna Bari(s)i(c) Tatsunori Shibata Edgardo Coda Zabetta

Foster Wheeler Energia Oy,Relanderinkatu 2,FI-78201 Varkaus,Finland Sumitomo Heavy Industries,Ltd.,5-2,Sobiraki-cho,Niihama,Ehime 792-8588,Japan

国际会议

The 11th International Conference on Fluidized Bed Technology(CFB-11)(第十一届流化床技术国际会议)

北京

英文

383-388

2014-05-14(万方平台首次上网日期,不代表论文的发表时间)