Optimization Research of Jetting Parameters for Conductor Installation in Deepwater

Jetting was widely used in deepwater conductor operation.Reasonable selection of drilling parameters is very important for conductor jetting in deepwater.Relational model between jetting ROP(penetration of rate) and the drilling fluid flowrate and WOB(weight on bit) parameters were established based on the lab experiment, field test and analysis of field application data, results show that flowrate and WOB parameters are the key factors for ROP of conductor jetting and the soaking time.The research achievement has been successfully applied in several deepwater wells in South China Sea, and it will provide scientific basis and technical guidance for deepwater well design and site operation.
Deep water Conductor Jetting WOB Drilling Fluid flowrate Field test
Jin Yang Bo Zhou De Yan Ruirui Tian Shujie Liu Jianliang Zhou Renjun Xie Guoxian Xu
Petroleum Engineering Laboratory of the Ministry of Education,China University of Petroleum,Beijing, CNOOC Research Center,Beijing,China
国际会议
SUT International Conterence on Subsea Technology and Deepwater Engineering(SUT 水下技术和深水工程国际会议)
深圳
英文
217-222
2012-09-25(万方平台首次上网日期,不代表论文的发表时间)