DETERMINATION OF INTERGRANULAR CORROSION SUSCEPTIBILITY OF Z3CN20.09M CAST DUPLEX STAINLESS STEEL BY A MODIFIED DOUBLE LOOP ELECTROCHEMICAL POTENTIOKINETIC REACTIVATION METHOD
In this study,a modified double loop electrochemical potentiokinetic reactivation(DL-EPR)test was applied to determine the degree of intergranular corrosion(IGC)susceptibility of a Z3CN20.09M cast duplex stainless steel(CDSS)which has been used widely in primary coolant pipes of nuclear power plants.An optimized DL-EPR measurement was successfully used to characterize the interactions among precipitates,chromium depletion and IGC of steel Z3CN20.09M with high sensitivity.The experimental results showed that the degree of sensitization increased gradually from 1h to 50h due to the formation of chromium-depleted phase γ2 around the M23C6 and σ phases precipitated at the ferrite/austenite boundaries or in ferrite during aging.
Intergranular corrosion DL-EPR Secondary phases
Y.Z.Shi B.Yang M.X.Zhang H.C.Wu S.L.Wang
State Key Laboratory for Advanced Metals and Materials,University of Science and Technology Beijing No.30 Xueyuan Road Beijing,100083,China
国际会议
Energy Materials 2014(第一届能源材料国际会议)
西安
英文
557-562
2014-11-04(万方平台首次上网日期,不代表论文的发表时间)