A Current Control Method for Quick-response and Disturbances-rejection on SAPF
Shunt active power filter with LCL output filter involves the tracking of transient current with high frequency harmonic components.The current control brings some complexity.This paper presents a kind of current control algorithm,which combines the triangle carrier comparison method with hysteresis control method.At the same time,the automatic self-correction of the grid-side disturbance while controlling current is discussed.The proposed algorithm is characterized by fast tracking of harmonic current,small computation capacity and easy implementation for engineering applications.Simulation and experiment verify the effectiveness of the proposed method.
Active Power Filter Pulse Width Modulation Regulator Adaptive Compensation
HU Jin-gao CHENG Guo-yang KUANG Qiu-xia
College of Electrical Engineering and Automation,FuZhou University,FuZhou,350116,China
国际会议
The 33th Chinese Control Conference第33届中国控制会议
南京
英文
6926-6930
2014-07-28(万方平台首次上网日期,不代表论文的发表时间)