The Design and Optimal on GMM Precision Pump
Designed a GMM precision pump for the existing membrane pump has the accuracy of low flow control precision,and analyzed the structure and working principle of the pump.Besides,the magnetic circuit and magnetic field of the pump has been simulated by the finite element ANSYS software and the modal analysis has been carried out on the concentric circles structure of elas-tomer.The results show that the design of the pump is reasonable.
GMM precision pump Simulate
Liu Dehui Liu Liwen Lu Quanguo Cao Qinghua Nie Qin
Institute of Micro/Nano Actuation and Control,NanChang Institute of Technology,NanChang 330099
国际会议
南昌
英文
1-6