A New Test Method for Heat Conductivity of Filling Fiber Assembly

  This paper designs a special apparatus for testing the heat conductivity of fiber assembly.It is different from fabric testing.For six filling fibers-wool,cashmere,kapok,hollow polyester,acrylic and goose down,tiieir heat conductivity with different bulk densities were measured.The results show tiiat tiie fiber morphological structures affect assembly characteristics.Bulk density is an important parameter which has a close relation witii the thermal transfer of fiber assembly.Controlling tiie assembly bulk densities to contain more still air is the crucial method for decreasing its heat conductivity.

Fiber Assembly Filling Heat Conductivity Thermal Insulation Bulk Density

Qian Liu Yan-Li Ma

College of Fashion,Shanghai University of Engineering Science,333 Longteng Road,Shanghai,201620,China

国际会议

第六届纺织生物工程及信息国际会议(The 6th Textile Bioengineering and Informatics Symposium )(TBIS2013)

西安

英文

1084-1089

2013-09-26(万方平台首次上网日期,不代表论文的发表时间)