会议专题

Conduction effect study of typical EMP on EED

  This paper selected the typical (EED) to study electromagnetic pulse injection effect test of EED according to conduction mode principle, and observed the rules of EMP with different characteristic parameters on EED.Results demonstrated that when the typical EMP has effect on EED by conduction mode, the injection energy depends on pulse width instead of rising time, pulse width is proportional to the injection energy of EED.50% ignition pulse energy of EED is no related pulse waveform parameters, and it is decided by EED parameters of its own.

EED electromagnetic pulse square wave injection effect test ignition energy

JI Xiangfei YAO Hongzhi FENG Qingmei ZHAO Tuan LIAN Kai

Science and Technology on Applied Physical Chemistry Laboratory Shaanxi Applied Physics-Chemistry Research Institute,Xian,Shannxi 710061,China

国际会议

2013 International Autumn Seminar on Propellants, Explosives and Pyrotechnics(2013国际推进剂、炸药、烟火技术秋季研讨会)

成都

英文

533-537

2013-09-24(万方平台首次上网日期,不代表论文的发表时间)