会议专题

Temperature Distribution of the Air Flow Field in Melt Blowing Process:Simulation and Measurement

  The melt blown nonwoven fabrics are characterized by superfine fiber structures.The key technology of achieving superfine fibers is the polymer drawing by the high velocity hot air jets.The temperature distribution of the air flow field has great influence on the polymer drawing.In this paper, the air temperature distribution of the dual slot die on an HDF-6D melt blowing nonwoven equipment is simulated and measured.The air flow field model of the dual slot die is established and solved numerically using the finite volume method and SIMPLE algorithm.The air temperature is measured with a temperature measuring system built for this research.Experimental results show that the simulation results of the air temperature coincide with the measured data which indicates the air flow flied model is effective.As this research is performed on an industrial melt blowing equipment, the results have great application values for actual production of melt blowing.

melt blowing air temperature numerical simulation measurement

Xiuqing Wang Chuan Xu Ting Chen Lili Wu

College of Textile and Clothing Engineering,Soochow University,Suzhou 215006,China Jiangsu China Nuclear Industry Huawei Engineering Design and Research CO.,LTD.,Nanjing 210019,China College of Textile and Clothing Engineering,Soochow University,Suzhou 215006,China;National Engineer

国际会议

The 8th China International Silk Conference (ISC2013)、The 4th Asian Protective Clothing Conference(APCC2013)and Eco-Friendly Textile Dyeing and Finishing Conference( 第八届中国国际丝绸会议、第四届亚洲防护服会议暨环保纺织染整会议)

苏州

英文

268-271

2013-09-09(万方平台首次上网日期,不代表论文的发表时间)