会议专题

Small-signal Analysis for Oil Particle Microfluidic Chip Based on Wavelet Transform

  Metal wear debris is a key component of contamination in lubrication oil,and an essential information carrier in hydraulic oil.A microfluidic method based on measuring the induction change is developed to detect metal particles in oil.A key advantage of this microfluidic chip is the very small distance between the particles inside oil and the embedded induction coil,which greatly improves the sensitivity of the detection.Wavelet transform methodology is carried out for the detection in this paper,experimental about iron particles smaller than 18μm and 38μm copper ones detection shows that this method is contributed to detect the small size metal particles for the microfluidic chip.

Metal Detector Microfluidic Chip Wavelet Transform

Xingming Zhang Hongpeng Zhang Yuqing Sun Haiquan Chen Yindong Zhang

Department of Marine Engineering Dalian Maritime University,Dalian,China

国际会议

The 9Th International Conference on Vibration Engineering and Technology of Machinery(第九届振动工程及机械科学技术国际会议)(VETOMAC-IX)

南京

英文

1-3

2013-08-20(万方平台首次上网日期,不代表论文的发表时间)