Study on the Towerless Calibration Method for Pulse Instrumentation Radar Based on Offset Dipole Compensation
Directional sensitivity and amplitude-phase consistent are the key factor that can affect the stability and precision of tracking targets for pulse instrumentation radar, so they need to be calibrated For the shortcomings of traditional tower calibration, the towerless calibration method based on offset dipole compensation is proposed And the feasibility is checked according to analysis of offset dipole compensation.The towerless calibrating system is designed and put into use in tracking a certain satellite.The tracking experiment indicates that the calibration result using towerless is superior to tower, and the system satisfies the demand of pulse instrumentation radar.
towerless calibration offset dipole directional sensitivity amplitude-phase consistence
Dong Jianwei Gao Changsheng Xiong Wei Huang Yangjun
Dept.of Astronautic Engineering,Harbin Institute of Technology,Harbin 150001,China;63623 Unit of PLA Dept.of Astronautic Engineering,Harbin Institute of Technology,Harbin 150001,China 63623 Unit of PLA,Lanzhou,732750,China
国际会议
哈尔滨
英文
478-481