Research on Compensation Method with Additional Phase for Quartz Crystal Test Network

  1EC recommended π network zero phase method is the standard one for testing parameters of quartz crystal resonator.Main difficulty in realizing such method is the compensation for additional phase shift of π network.π network can be inspired by multiplexed output standard signal adjusted by phase difference.After testing the additional phase shift of π network, and then adjusting the phase difference of signal source, actively compensating the additional phase shift of network, the test precision can be significantly improved and requirements for π network manufacturing technology and operating environment will be lowered.

Quartz Crystal Resonator Test Phase Deviation Compensation

Li Dong Wang Yanlin Liu Guili Liu Gang

Beijing Key Laboratory of Measurement& Control Technology,Beijing Information Science & Technology University No.12 Xiao Ying East Road,Haidian Dist,Beijing,China