Study on recombination finish technology of flame retardant and hydrophilic of polysulfonamide/viscose blended fabric
The experiments of flame retardant and hydrophilic finish were carried out on polysulfonamide/viscose blended fabric.The flame-retardant agent and hydrophilic agent were selected and their dosages were optimized.The results showed that when the flame retardant agent was FPK 8002 and the hydrophilic agent was DP-9993, the optimum conditions of finish process was determined as follows: the blend ratio were 70/30, 60/40 and 50/50, the dosages of FPK8002 were 60,90,160g/L and the dosages of resin were 20, 30, 40g/L respectively.The dosage of DP-9993 was 10g/L.The multi-function including hydrophilic, flame retardant, wet gas absorption and UV protection could be composited when the method was that the hydrophilic finish was first and the flame retardant was followed.
polysulfonamide viscose flame-retardant hydrophilic agent testing
Guo-Chun Li Yong Shen
Shanghai University of Engineering and Science, Shanghai, 201620, China
国际会议
上海
英文
190-196
2013-07-05(万方平台首次上网日期,不代表论文的发表时间)