Research on Cold Cracks of Welding 700MPa Grade High Strength Low Alloy Steel Sheet
Cold cracks resistance of welding 700MPa grade high strength low alloy was studied by Y-groove cracking test.The effects of cold cracks resistance with different strength grade welding wire and welding parameters were analyzed.The results show that it is unnecessary to conduct heat treatment due to the low quenching tendency for 700MPa grade high strength low alloy steel sheet.It would have low weld cold cracks sensitivity under welding with two different strength grade welding wire.
700MPa grade HSLA Cold cracks sensitivity Y-groove cracking test
Zhang Wu Liu Yonggang Hu Xuewen
Maanshan Iron&Steel Co.Ltd. Anhui,243000,China
国际会议
The 2nd International Symposium on Automobile Steel (第二届汽车用钢生产及应用技术国际研讨会)
鞍山
英文
183-185
2013-05-21(万方平台首次上网日期,不代表论文的发表时间)