Multi-frequency Proportional-resonant Control for Wave Power Generation System
A grid voltage vector oriented proportional resonant (PR) control strategy is applied to the grid current control of the float-type wave power generation system.Compared with the conventional double closed-loop proportional integral (PI) control method,the proposed multi-frequency PR control method can realize zero steady-state error in AC input signal in the stationary frame,without complex coordinate rotation transformation and decoupling control.The overall wave power generation system model is built with Matlab/Simulink to evaluate the performance of the PR control method.Simulation results have shown that the PR control can well improve the robustness and the power quality of the float-type wave energy conversion control system.
wave power generation current control voltage vector orientation proportional resonant control
Fang Hongwei Cheng Jiajia Yang Qiwei Lian Jing
School of Electrical Engineering and Automation,Tianjin University,Tianjin,300072,China Chemical Industry Press,Dongcheng District,Beijing,100011,China
国际会议
郑州
英文
993-997
2013-10-19(万方平台首次上网日期,不代表论文的发表时间)