Analysis of Vibration Caused by Electromagnetic Force on Stator End-winding of Large Dry Submersible Motor
This paper investigates the vibration which caused by electromagnetic on the stator end-winding of the large dry submersible motor.Firstly,the electromagnetic field which included transition state and steady state is researched by 3-D FEM.Secondly,the electromagnetic force which lead to vibrations of end-winding is calculated by numerical method,it can be obtained that where endured the largest force density along the slant part of end-winding.Finally,the radial displacement and the axial displacement of the slant part which caused by vibrations is studied,the analysis results show that the axial displacement is larger than the amplitude of radial displacement.It indicates that the slant part of end-winding will be more easily damaged at axial direction than radial direction
Dry submersible motor Electromagnetic force Finite element method Vibration
Li Shan Xiaowei Cheng Yong Fang Xiaohua Bao
Hefei Hengda Jianghai Pump Co., Ltd. Hefei, China School of Electrical Engineering and Automation, Hefei University of Technology, Hefei, China
国际会议
杭州
英文
1-4
2013-07-07(万方平台首次上网日期,不代表论文的发表时间)